Gas detection unit MX16

Gas detection unit MX16
Gas detection unit MX16
Certification BE ATEX

WHY CHOOSE BE ATEX

  • Re-calibrate of gas detection equipments
  • Check and verify of all PPE equipements
  • Customised configuration of all devices
Entête

The single channel gas detection system for simple applications.

The MX16 is a digital or analog 1 channel unit for simple applications. It is designed to measure a single gas present in the atmosphere such as: O₂, CO₂, CH₄, H₂ and LPG.

Some application examples:

  • Anoxia (O₂) detection for laboratory applications
  • CO₂ detection during yeast fermentation in breweries or must fermentation in viticulture
  • Gas detection in small boiler rooms or battery charging rooms

Small and easy to use, the unit is available in different versions:

VERSION 1 line for 1 analogical detector 4-20mA: O₂ (0-30% Vol.), CO₂ (0-5 % Vol), CH₄ (0-100% LEL), GPL (0-100% LEL), H₂ (0-100% LEL)

EASY DUO VERSION 1 line for 1 digital sensor: OLCT 10N O₂ (0-30% Vol) OLCT 10N CO₂ (0-5 % Vol)

Also compatible with iTrans 2, OLCT 80, Meridian, OLCT 710 or any other analog sensor.

Characteristics

Attribut
Size
Valeur
265 x 266 x 196 mm
Attribut
Weight
Valeur
1,8 kg
Attribut
Protection Class
Valeur
IP55
Attribut
Operating temperature
Valeur
-20°c to +50°c
Attribut
Humidity
Valeur
5 to 95% RH not condensed
Attribut
Power supply
Valeur
100-240 Vca 50-60Hz (35W)
Attribut
Consumption
Valeur
250mA max (without sensor)
Attribut
Approval
Valeur
Complies with the Low Voltage Directive according to EN 61010-1:10
EMC compliant according to EN 50270:15
Attribut
Warranty
Valeur
2 years

Features

INPUT CHARACTERISTICS

Lines of measurement :

  • digital: 1, RS 485, proprietary protocol, 9600 Baud, Industrial network cable, 2 shielded twisted pairs
  • analog: 1 (4-20mA), Input range 0 to 23mA (4-20mA reserved for measurement), Load resistance 120 Ohm, Shielded cable 1 pair or 1 third depending on detector

Current available on the channel: 0.42A (at 50°C) to 1A (at 30°C) with internal AC supply

ALARMS & OUTPUTS

Number of alarms per channel: 4 alarm levels (Al1, Al2, negative drift, overrange) + Fault, Doubtfulness for explosive gases, Al1 and Al2 alarm thresholds accessible and modifiable, manual acknowledgements

Internal relays: 2 alarm relays + 1 fault relay (non-programmable), positive safety, potential-free dry contacts, RCT, 5A/250Vac-30Vdc

Digital output: RS485 Modbus RTU protocol

Gas detection unit MX16 - User reviews

Add a review & rate this product

* required fields

Restricted HTML

  • Allowed HTML tags: <a href hreflang> <em> <strong> <cite> <blockquote cite> <code> <ul type> <ol start type> <li> <dl> <dt> <dd> <h2 id> <h3 id> <h4 id> <h5 id> <h6 id>
  • Lines and paragraphs break automatically.
  • Web page addresses and email addresses turn into links automatically.