UNIPOINT Controller

UNIPOINT Controller
Certification BE ATEX

WHY CHOOSE BE ATEX

  • Re-calibrate of gas detection equipments
  • Check and verify of all PPE equipements
  • Customised configuration of all devices
Entête

The flexible and affordable din-rail-mounted controller for system integrators.

The Unipoint is a simple DIN-rail-mounted controller that provides system integrators with a flexible and affordable way to incorporate their flammable, toxic or oxygen gas detectors into their control system.

The Unipoint can be easily installed in any plastic or metal enclosure for use indoors or outdoors and even in potentially explosive atmospheres. Small- to medium-sized monitoring solutions can be created by connecting multiple Unipoints. Each unit has audiovisual alarms, three programmable alarm relays and a fault relay.

Characteristics

Attribut
Size
Valeur
5.5 x 11.8 x 5.9 in. / 14.0 x 30 x 15.5 cm
Attribut
Weight
Valeur
7.94 oz / 225g (controller only)
Attribut
Operating temperature
Valeur
+14 to +131°F (-10 to +55°C)
Attribut
Humidity
Valeur
10 - 90% RH (non-condensing)
Attribut
Protection Class
Valeur
Inside, IP3x
Attribut
Warranty
Valeur
2 years
Attribut
Approval
Valeur
EMC/RFI: EN50270
Electrical Safety: EN61010, UL61010b
Performance: ATEX measuring function EN60079-29-1, SIRA10ATEX8243X
CE, TUV
Attribut
Additional feature
Valeur
External battery (optional)
Attribut
Power supply
Valeur
Nominal 24VDC (18-32VDC)

Features

INPUT SPECIFICATIONS

  • Available lines: one input available in mV or 4-20mA
  • Nominal voltage: nominal 24V DC (18-32V DC)
  • Maximum power per line: mV detector = 4.8W (including power to detector) mA detector = 3.0W (excluding power to three-wire detector)

ALARMS

  • Relays: four relays available
  • Type: SPCO/3A, 240V AC/28V DC (non-inductive load)
  • Alarm levels: three alarm levels (Al1, Al2, Al3) + fault, Integrated audiovisual alarms
  • Programming:
    • Alarms: latching/non-latching - Energised/de-energised
    • Alarm trip point: rising/falling
    • Alarm on/off time delay: (0 to 900 seconds)
  • Fault: latching/non-latching - Energised/de-energised
miniature

UNIPOINT Controller - User reviews

Add a review & rate this product

* required fields

Restricted HTML

  • Allowed HTML tags: <a href hreflang> <em> <strong> <cite> <blockquote cite> <code> <ul type> <ol start type> <li> <dl> <dt> <dd> <h2 id> <h3 id> <h4 id> <h5 id> <h6 id>
  • Lines and paragraphs break automatically.
  • Web page addresses and email addresses turn into links automatically.