HORA 130 Breathing Air Monitoring Unit

HORA 130 Breathing Air Monitoring Unit
Certification BE ATEX

WHY CHOOSE BE ATEX

  • Re-calibrate of gas detection equipments
  • Check and verify of all PPE equipements
  • Customised configuration of all devices
Entête

The unit that tests breathing air quality during asbestos removal.

The HORA 130 area monitor has been specially designed to monitor air quality for mobile teams and on worksites as per the ETST 1309168A order of 8 April 2013.

The device continuously measures concentrations of CO, CO₂, O₂, water vapour, oil vapour and VOCs.

A programming algorithm continuously ensures that the sensors and the connected alarms are working properly.

An integrated SD card and a comms port can be used to extract the readings taken.

The electrical and pneumatic outputs can be used to manage remote alarms.

Characteristics

Attribut
Size
Valeur
14.5 x 11.8 x 5.1 in. (37 x 30 x 13 cm)
Attribut
Weight
Valeur
26.5 lbs (12kg)
Attribut
Operating temperature
Valeur
+14°F to +113°F (-10 to +45°C) with heating option
Attribut
Humidity
Valeur
95% RH, non condensing
Attribut
Protection Class
Valeur
IP54
Attribut
Housing materials
Valeur
Rubber
Attribut
Power supply
Valeur
230V ±15% or battery
Attribut
Consumption
Valeur
1 A
Attribut
Pressure
Valeur
2-10 bars
Attribut
Output
Valeur
30 l/h
Attribut
Connection
Valeur
Cable inlet 4 x 8 mm
Attribut
Warranty
Valeur
2 years

Features

  • Measurement: CO, CO₂, O₂, H₂O and oil (in continuous)
  • Low analysis rate (30 litres/hour)
  • Real-time measurements on a monochrome screen
  • Adjustable thresholds (adjusted according to the decree of 8 April 2013)
  • Sensors calibration from the display screen
  • Continuous flow control in the cells
  • Watchdog functions for all faults and alarms
  • Traceability of measurements on SD card
  • Reduced Maintenance CostPositive safety of all defects
  • Electrical control for alarm
  • Pneumatic control for horn (pneumatic)
  • Triggering of alarms in the event of a power failure
  • Measurement and low pressure alarm option available
  • Dismantling speed
  • Sensors integrated in an interchangeable cell block
  • Possible option of automatic cell calibration O₂
  • Setting of the automatic hygrometry alarm threshold as a function of temperature

HORA 130 Breathing Air Monitoring Unit - User reviews

Add a review & rate this product

* required fields

Restricted HTML

  • Allowed HTML tags: <a href hreflang> <em> <strong> <cite> <blockquote cite> <code> <ul type> <ol start type> <li> <dl> <dt> <dd> <h2 id> <h3 id> <h4 id> <h5 id> <h6 id>
  • Lines and paragraphs break automatically.
  • Web page addresses and email addresses turn into links automatically.