GASMONITOR PLUS Controller

GASMONITOR PLUS Controller
GASMONITOR PLUS Controller
GASMONITOR PLUS Controller
Certification BE ATEX

WHY CHOOSE BE ATEX

  • Re-calibrate of gas detection equipments
  • Check and verify of all PPE equipements
  • Customised configuration of all devices
Entête

The flexible, modular gas detection control panel that can be installed in a rack.

The Gasmonitor Plus is a flexible system that has already proven its worth for countless projects across the world, including offshore applications.

The Gasmonitor Plus can manage up to 16 gas detectors, or up to 32 zones if used for fire protection.

With its innovative features (individual bar graph per channel, alarms programmable per detector) and its SIL2 safety approval, this control panel is fully capable of handling the most demanding applications.

Associated fixed gas detectors: Xgard, Xsafe, XgardIQ, TXgard IS+, TXgard Plus, F-Gas, Flamgard Plus, IREX infrared

Characteristics

Attribut
Size
Valeur
19 x 5.25 x 11.5 in. (48.3 x 13.3 x 29.4 cm)
Attribut
Weight
Valeur
21lbs (9.5kg)
Attribut
Operating temperature
Valeur
0°C to +50°C (32°F to 122°F)
Attribut
Humidity
Valeur
0-95% non-condensing
Attribut
Housing materials
Valeur
Aluminium alloy
Attribut
Power supply
Valeur
100-260 V ac 50/60 Hz external, 27.6 V dc
Attribut
Consumption
Valeur
300 W max.
Attribut
Additional feature
Valeur
Battery back-up External
Attribut
Approval
Valeur
Low voltage directive Meets BS EN 61010-1
EMC Directive Meets EN 50082-1, EN 50081-1, EN 50270, EN61000-6-4
ATEX Conforms to EN60079-25 in configuration with Zener Barrier
Baseefa 05Y0090/1
Attribut
Warranty
Valeur
1 year

Features

INPUT SPECIFICATIONS

  • Available lines: Gas: up to 16 detectors (4-20mA or mV); Fire: maximum of 32 loops per rack (16 twin zone fire modules)
  • Nominal voltage: 18-30V DC, to suit the architecture
  • Maximum total current for the lines: 3.3A

ALARMS

  • Relays: up to 84 double-pole change-over (DPCO) contacts, Interrupting rating 5 A @ 250 V AC
  • Alarms per channel: gas alarms 1, 2 and 3, fire and fault, Programming: user-configurable (energized/de-energized, latching/non-latching, time delay)
  • Audible/visual alarm command: Powered 24V DC, max. load up to 2A for each alarm level

OUTPUTS

  • Analogue output: one 4-20mA repeat output available per detector / Max. load: 960 Ohms or a 1-5V output available per detector / Min. load: 100 Ohms
  • Digital communication: RS-232